Remarks When cards are used, power modules with a power of 240 W or higher must be used.

Certification EMC certification Safety certification Manufacturing certification

Chassis material Metal

Static power consumption [W] 77

Number of card slots 2

Dimensions without packaging (H x W x D) [mm(in.)] Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 454.0 mm (1.72 in. x 17.4 in. x 17.87 in.)

Dimensions with packaging (H x W x D) [mm(in.)] 145.0 mm x 650.0 mm x 550.0 mm (5.71 in. x 25.59 in. x 21.65 in.)

Chassis height [U] 1

Installation type Rack mounting,Desk mounting

Weight without packaging [kg(lb)] 6.31 kg (13.91 lb)

Weight with packaging [kg(lb)] 8.76 kg (19.31 lb)

Typical power consumption [W] 30% traffic under the ATIS standard and dual power modules: - 122 W (with two 180 W AC power modules) - 118 W (with two 240 W DC power modules)

Typical heat dissipation [BTU/hour] 30% traffic under the ATIS standard and dual power modules: - 416.26 (with two 180 W AC power modules) - 402.61 (with two 240 W DC power modules)

Maximum power consumption [W] 100% traffic under the ATIS standard and dual power modules: - 127 W (with two 180 W AC power modules) - 123 W (with two 240 W DC power modules)

Maximum heat dissipation [BTU/hour] 100% traffic under the ATIS standard and dual power modules: - 433.32 (with two 180 W AC power modules) - 419.67 (with two 240 W DC power modules)

MTBF [years] 47.17

MTTR [hours] 2

Availability > 0.99999

Noise at normal temperature (acoustic power) [dB(A)] 54.2 dBA

Noise at high temperature (acoustic power) [dB(A)] 45°C (113°F): 61.5 dBA

Noise at normal temperature (acoustic pressure) [dB(A)] 41.2 dBA

Number of power slots 2

Number of fans modules 2

Maximum number of physical ports on the entire device 50

Maximum number of 100GE ports 2

Maximum number of 40GE ports 2

Maximum number of 25GE ports 8

Maximum number of 10GE ports 24

Maximum number of 2.5GE ports 24

Maximum number of GE ports 48

Maximum number of FE ports 40

Redundant power supply 1+1 Pluggable AC and DC power modules can be used together on the same device. Note: Power modules with fans and power modules without fans cannot be installed on the same device.

Long-term operating temperature [°C(°F)] –5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.)

Short-term operating temperature [°C(°F)] -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.)

Restriction on the operating temperature variation rate [°C(°F)] When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met: - The operating temperature can exceed 45°C (113°F) for a maximum of 96 consecutive hours in a year. - The total time when the operating temperature exceeds 45°C (113°F) in a year is less than or equal to 360 hours. - The number of times the operating temperature exceeds 45°C (113°F) is less than or equal to 15 in one year. If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur. Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km.

Storage temperature [°C(°F)] –40°C to +70°C (–40°F to +158°F)

Long-term operating relative humidity [RH] 5% RH to 95% RH (non-condensing)

Long-term operating altitude [m(ft.)] 0–5000 m (0–16404 ft.)

Storage altitude [m(ft.)] 0-5000 m (0-16404 ft.)

Power supply mode Pluggable power supply

Rated input voltage [V] - AC input: 100 V AC to 130 V AC, 200 V AC to 240 V AC; 50/60 Hz - High-voltage DC input: 240 V DC - DC input: –48 V DC to –60 V DC

Input voltage range [V] - AC input: 90 V AC to 290 V AC; 45 Hz to 66 Hz - High-voltage DC input: 190 V DC to 290 V DC - DC input: -38.4 V DC to -72 V DC

Maximum input current [A] The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules.

Console port RJ45

Eth Management port RJ45

USB Supported

Dying gasp Supported

RTC Supported

Power supply surge protection [kV] - Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode - Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode

Ingress protection level (dustproof/waterproof) IP20

Types of fans Pluggable

Heat dissipation mode Air cooling for heat dissipation, intelligent fan speed adjustment

Airflow direction Air intake from front and right and air exhaust from rear




Stránky o produkte:
https://ekit.huawei.com/#/ekitShop/shopDetail?merchandiseId=1480064119431291776&offShelf=false&countryCode=SK&lang=en